Configure FA Management on a Port or MLT
Use this procedure to configure a management I-SID on a Fabric Attach (FA)-enabled port or MLT.
To configure an FA management I-SID for Auto-sense-enabled ports, see Configure a Management I-SID for Auto-sense Fabric Attach Proxy Switches.
Before you begin
Ensure that the port or MLT is enabled for FA.
About this task
This command applies to all traffic sent or received on a port or MLT, carrying the VLAN ID specified using the c-vid parameter. This parameter is optional.
Depending on whether the c-vid parameter is specified or not, the behavior is as follows:
-
If you specify the c-vid parameter, the FA Server transmits this VLAN ID as the management VLAN in the FA Element TLV. A client or proxy receiving this TLV uses this VLAN-ID for management traffic on the FA Server uplink.
-
If you do not specify the c-vid parameter, the FA Server transmits a management VLAN with a VLAN ID value of 4095 in the FA Element TLV. A client or proxy receiving this TLV uses untagged traffic for network management on the FA Server uplink.
An FA management I-SID can have a platform VLAN associated with it. For Layer 3 support on the management I-SID, you must create a platform VLAN by port and associate the platform VLAN with the management I-SID. The C-VID can be of the same value or of a different value than that of the platform VLAN.
If the management I-SID matches one of the FA Switched UNI (ELAN) I-SIDs (as displayed by the command show i-sid elan), then the platform VLAN is automatically associated with the FA-enabled interface (port or MLT).
Procedure
Examples
Configure FA management on port 1/2:
Switch:1>enable Switch:1#configure terminal Enter configuration commands, one per line. End with CNTL/Z. Switch:1(config)#interface gigabitethernet 1/2 Switch:1(config-if)#fa management i-sid 101 c-vid 101
Switch:1(config-if)#show i-sid 101 ======================================================================================== Isid Info ======================================================================================== ISID ISID PORT MLT ORIGIN ISID ID TYPE VLANID INTERFACES INTERFACES NAME ---------------------------------------------------------------------------------------- 101 ELAN 3 - - CONFIG EXTRSERVER_101
The following example demonstrates the Origin as "auto-sense".
Switch:1(config-if)#show i-sid 500 ======================================================================================== Isid Info ======================================================================================== ISID ISID PORT MLT ORIGIN ISID ID TYPE VLANID INTERFACES INTERFACES NAME ---------------------------------------------------------------------------------------- 101 ELAN - c300:1/45 - AUTO-SENSE ISID_500
Switch:1(config-if)#show interfaces gigabitEthernet i-sid ================================================================================== PORT Isid Info ================================================================================== ISID ISID ISID MAC PORTNUM IFINDEX ID VLANID C-VID TYPE ORIGIN NAME BPDU SUNI ---------------------------------------------------------------------------------- 1/2 193 101 3 101 ELAN MANAGEMENT EXTRSERVER_101 ---------------------------------------------------------------------------------- 1 out of 1 Total Num of i-sid endpoints displayed
Configure FA management on MLT 10.
Switch:1>enable Switch:1#configure terminal Enter configuration commands, one per line. End with CNTL/Z. Switch:1(config)#interface mlt 10 Switch:1(config-mlt)#fa management i-sid 101
Verify configuration of FA management on the MLT. Because the C-VID is not specified, the MLT displays as untagged.
Switch:1(config-mlt)#show i-sid 101 ======================================================================================== Isid Info ======================================================================================== ISID ISID PORT MLT ORIGIN ISID ID TYPE VLANID INTERFACES INTERFACES NAME ---------------------------------------------------------------------------------------- 101 ELAN 3 - u:10 CONFIG EXTRSERVER_101
In the following example, for Layer 3 support, create a platform VLAN 3 and associate it with the management I-SID 101.
Switch:1(config-if)#vlan create 3 type port-mstprstp 0 Switch:1(config-if)#vlan i-sid 3 101
Switch:1(config)#show i-sid ==================================================================================================== Isid Info ==================================================================================================== ISID ISID PORT MLT ORIGIN ISID ID TYPE VLANID INTERFACES INTERFACES NAME ---------------------------------------------------------------------------------------------------- 15999999 ELAN 4048 - - C --- - --- - - Onboarding I-SID 16777001 ELAN N/A - - C --- - --- - - FAN-ISID c: customer vid u: untagged-traffic All 2 out of 2 Total Num of i-sids displayed ORIGIN Legend: C: manually configured; D: discovered by FA or EPT M: FA management; E: discovered by EAP; A: auto-sense; R: multi-area redist l: discover by local switch r: discover by remote VIST switch
Switch:1(config-if)#show vlan i-sid ==================================================================== Vlan I-SID ==================================================================== VLAN_ID I-SID I-SID NAME -------------------------------------------------------------------- 1 2 3 101 EXTRSERVER_101 33 999
Because the management I-SID matches one of the FA Switched UNI (ELAN) I-SIDs, the platform VLAN is automatically associated with the FA-enabled port 1/2.
Switch:1(config-if)#show interfaces gigabitEthernet i-sid ================================================================================== PORT Isid Info ================================================================================== ISID ISID ISID MAC PORTNUM IFINDEX ID VLANID C-VID TYPE ORIGIN NAME BPDU SUNI ---------------------------------------------------------------------------------- 1/2 193 101 3 101 ELAN MANAGEMENT EXTRSERVER_101 ---------------------------------------------------------------------------------- 1 out of 1 Total Num of i-sid endpoints displayed
Variable Definitions
The following table defines parameters for the fa management command.
Variable |
Value |
---|---|
i-sid<1-16777215> |
Specifies the management I-SID. |
<1-4094> |
Specifies the customer VLAN ID. Important:
If you do not specify a C-VID value, the port or MLT is untagged. |